Da Vinci Permium

Da Vinci Permium

Ceiling
French French

The Da Vinci Permium is an innovative multi-purpose single detector DR system designed to provide maximum versatility
for general radiology, trauma andemergency applications.
The automated functions allow for a maximum number of exams in a minimum amount of time. The Da Vinci Permium 
provides all the benefits of a digital system, including increased workflow and excellent image quality.
Specifications
Please be aware that the features/specifications can differ from country to country
Weight:
Vertical bucky stand
220 kg
Elevating table
225 kg
Manual and auto-tracking model
162 kg
Automatic model
172 kg
Power cabinet
62 kg
X-ray Tube
Type
Rhenium-tungsten molybdenum rotating anode
Anode size
102 mm
Voltage
150 kV
Anode speed
3000 - 9000 tr/min
Anode angle
13°
Nominal focal point size
0.6-1.2 mm
Nominal anode input power (for the equivalent anode input power of 125 W): Small / Large
9000 tr/min / 43 kW / 100 kW
Maximum filament current
5.4 A
Maximum anode heat content
600 kHU (450 kJ)
continuous heat dissipation
1000 W (80 kHU/min)
Maximum heat dissipation
1500 W (125 kHU/min)
Generator
Application
Radiography
High frequency
150 kHz
kV selection
40 - 150 kV, with 1 kV steps
Exposure time
0.001 - 6.4 sec, with 26% steps
mAs range
0.1 - 1000 mAs
Quantity of X--ray tube output
1 or 2
Anatomical Programs (APR)
Unlimited
Anode speed
3000 - 9000 tr/min
AEC Interface
4 ionisation chambers max (solid state ionisation 3 fields)
mA Range
10-1000 mA
Collimator
Model
Ralco R302®
Field coverage
Square field: Continuous film coverage up to 43 x 43 cm at 90 cm Focus Film Distance (±1%)
Collimator rotation
± 45°
Inherent filtration
Minimum filtration 2 mm aluminium equivalent (0.3 mm and 1 mm on request)
Light source
High luminosity provided by a quartz iodide lamp
Indicator and digital reading
LED indicators on the front panel show the mode of operation
Radiation shielding
150 kVp – 4 mA
Relation with the detector tray unit
Possibility of manual operations with override capability from the stand (for optional automatic collimation)
Detector
Model
Trixell Pixium 4600®
Technology
Flat panel / Amorphous silicon (CsI) photodiodes array with high absorption and high resolution scintillator screen
X-ray generator voltage range
40 to 150 kVp
X-ray exposure
1.25 to 2.5 µGy
X-ray maximum linear dose
30 µGy
Pixel pitch
143 µm
X-ray sensing surface
3001 x 3001 pixels / 43 x 43 cm (17 x 17”)
Spatial resolution
3.5 lp / mm
DQE at 0.1 pl / mm
65%
Dynamic range
14 bits (16 384 grey levels)
Table
Tabletop absorption
0.9 mm Al eq
Tabletop to film distance
7 cm
Motorized tabletop height
53.3 to 85.3 cm
Tabletop height speed
3 cm/sec
Tabletop dimensions
220 X 80 cm
Longitudinal movement of the table top
±38 cm
Lateral movement of the table top
±13 cm
Bucky longitudinal travel
50.5 cm
AEC measuring chamber
Predisposed for 3 fields ionization chamber
Vibrating grid
R=10 : 1, F=100, 40 l/cm (other grid available on request)
Cassette Size
Up to 35x43 cm
Maximum patient weight
150 kg (200 kg with carbon fibre table top*)
Weight
280 kg
Standard accessories
Patient handgrips

Elevating table:

. Table top dimensions: 220 x 89 cm / . Elevation: 52 to 92 cm

Ceiling suspension:

. Fully motorized 5-axis ceiling suspension / . Manual override capability / . Auto-tracking and auto-positioning / . Patient side color touch screen for system control

Vertical bucky stand:

. Floor-mounted stand / Detector tilting -20° / 90° / . Vertical range: 150 cm

Bucky:

. Oscillating grid // . 40 l/cm / R: 10:1 / F: 110 cm 180 cm // . 60 l/cm / R: 12:1 / F: 110 cm 180 cm // . Conventional or sensing

Generator:

. 150 kHz // . 50 to 80 kW power rating

X-ray tube:

From 400 to 1,000 kHU anode heat storage capacity

Automatic collimator:

. Manual and automatic // . Motorized filters with automatic filter selection (option)
Manuals